1
|
Stand Alone Outdoor PIR [With Light]
|
|
|
|
|
*
|
Power Requirement : AC 220~240v/50Hz
|
|
*
|
Power Cord Requirement : H05RN-F, 1.0sq.mm
|
|
*
|
Lighting Load: Max-1000W Incandescent or Max-40W×10 Fluorescent
|
|
*
|
Detection Angle : Upto 110° or 180° at 20°
|
|
*
|
Swiveling Angle : Vertical 35° , Horizontal 70°
|
|
*
|
Wall Switch Control : On / Off
|
|
*
|
Mounting Height : Recommended
|
|
|
1.8~2.0m (5.9~6.6ft)Wall Mount
|
|
|
2.5~4.0m (8.2~13.1ft) Ceiling Mount
|
|
*
|
Wall Switch Control : On / Off
|
|
*
|
Sensor Operation : Auto
|
|
*
|
Time Adjustment : 5±3 Sec ~ 12±3 Min
|
|
*
|
Lux Adjustment : Approx 0~1000 Lu
|
|
*
|
Operating Temperature : -20 °C ~ +40° C
|
|
*
|
Warm Up Time : About 1 Min.
|
|
*
|
Protection Class : II
|
|
*
|
Protection Degree : IP 44
|
|
*
|
Safety : CE, GS
|
Specifications of Hooter:
|
|
|
|
Compatible with all alarm control panels
|
|
Acoustic signal-piezo buzzer
|
|
Optical signal-5W/12V light bulb
|
|
3 different sounds available
|
|
Highly resistant polycarbonate housing
|
|
Tamper protection
|
|
-against opening
|
|
-against pull-off
|
|
Galvanized steel inner cover
|
|
Impregnated electronic circuits
|
|
Optional hermetic magnetic contact
|
Specifications of LMC (Light Duty Magnetic Contact)
|
Breakdown Voltage
|
100v / Max
|
|
Switch Current
|
0.5A
|
|
Wire:
|
22AWG with armored cable
|
|
Dimension
|
104.5x44.5MM
|
|
Enclosure
|
Aluminum Case
|
Specifications of Panic Switch:
|
Contact Rating
|
10W/VA
|
|
Switching Voltage (Max.)
|
200 VDC
|
|
Switching Current (Max.)
|
0.5 Amp.
|
|
Contact Resistance (Min.)
|
150 milli ohms
|
|
Life Expectancy
|
10x 10 6 Operations
|
|
Insulation Resistance
|
10 9 ohms
|
|
Shock Resistance
|
30G for 11mSec.
|
|
Vibration Resistance
|
20G ( 10 to 1000Hz)
|
|
Magnets
|
ALINCO/ Rare Earth (Unless otherwise specified)
|
|
Armour Jacket
|
Stainless Steel (Type 304)
|
|
Plastic Material
|
ABS Plastic (Unless otherwise specified
|
|
1
|
Passive Infrared Detector
|
|
|
|
|
*
|
Infrared Sensors : Dual Element
|
|
*
|
Power Supply : 9~16 VDC, 12 V typical
|
|
*
|
Current Drain : 10 ma, 12 VDC
|
|
*
|
Alarm Output : NC/NO 30 VDC, 0.2A max.
|
|
*
|
Alarm Period : 2±0.5 Sec
|
|
*
|
Pulse Count : 2-3 Selectable
|
|
*
|
Tamper Switch : NC Cover Open Activates
|
|
*
|
Walk Test LED - Red Can Be Disabled
|
|
*
|
RFI immunity : Avg. 20 V/m, (10~1000 MHz)
|
|
*
|
Detectable Speed : 0.3~1.5 m/Sec
|
|
*
|
Mounting Height : 2.2 m typical
|
|
*
|
Humidity : 95% RH Maximum
|
|
*
|
Temperature : -20° C ~ 60°C (-4°F ~ 140°F)
|
|
*
|
Note: PIR Does Not Sens Pats
|
|